DESCRIPTION
PERMACOAT 6500 is a 100% solids epoxy novolac containment and/or floor coating system. The PERMACOAT 6500 is specifically designed as a containment product for industrial solvents and acids.

The PERMACOAT 6500 consists of two components, resin and hardener, in both the horizontal and vertical formulations. Its application is accomplished with rubber squeegees and short nap paint rollers.

FUNCTION
PERMACOAT 6500 is designed as a 60-250 mil secondary containment/floor system where exposure to harsh chemicals such as Nitric Acid, Glacial Acetic Acid, Ethylene Dichloride or N-Methyl-2-Pyrrolidone are anticipated. PERMACOAT 6500 can be installed over most sound substrates, including new or old concrete, and many types of repair mortar. 

TYPICAL APPLICATIONS

  • Sumps
  • Trenches
  • Chemical process floors
  • Tank farm containment
  • Chemical loading and unloading areas
  • Drum storage areas

FEATURES
PERMACOAT 6500 containment system allows for fast, easy applications with minimal downtime.

PERMACOAT 6500 is monolithic and nonporous, eliminating the most common avenues of flooring/containment failure (i.e. seams and porosity).

The resinous PERMACOAT 6500 system exhibits very high physical properties, approximately 3-4 times those of standard concrete.

OTHER FEATURES INCLUDE:

  • Low odor
  • Non-skid safety finish 
  • Non-flammable

MIXING & APPLICATION
For mixing and application information, please refer to the PERMACOAT 6500 Application Bulletin.

WARRANTY
For product warranty see ChemProof Polymers, Inc. "Standard Limited Warranty." If one is not included with this literature contact your local distributor or ChemProof Polymers, Inc. for a copy.

TYPICAL PROPERTIES

Solids, by Volume   100%

Compressive Strength 
ASTM C579
12,000 psi

Flexural Strength ASTM D790 14,000 psi

Tensile Strength
ASTM D307
10,000 psi

Bond Strength to Concrete
ASTM D4541
Exceeds tensile strength of concrete. Failure in concrete

Taber Abrasion
ASTM D4060
CS 17 Wheels
Loss/1000
cycles = 25mg

Hardness Shore D
ASTM D2240
80

 
PACKAGING & COVERAGE
PERMACOAT 6500 resin and primer are packaged in one and three gallon units. Each unit consists of pre-measured components, Part A (Resin) and Part B (Hardener). 

Application thickness may vary from 80-250 mils, depending on the expected service conditions. Factors to consider are 1) length of chemical exposure; 2)mechanical abuses; and 3) substrate texture.

SAFETY
PERMACOAT 6500 contains blended Epoxies as the resin and blended Amines as the hardener. Protective clothing and gloves are recommended to prevent sensitization to these materials. In case of ingestion or eye contact, contact a physician immediately. MSDS are available for this product upon request.

 

WHERE PERMACOAT 6500 SHOULD NOT BE INSTALLED
PERMACOAT 6500 should not be applied over substrates:

  • subject to hydrostatic pressure
  • which are unsound
  • which are contaminated and cannot be cleaned
  • at temperatures below 60oF (consult ChemProof Polymers)